摘要:依據用電設備的功率因數,可測算輸電線路的電能損失。通過現場技術改造,可使低于標準要求的功率因數達標,實現節電目的。本文分析了無功補償的作用和補償容量的選擇方法,著重論述了低壓電網和異步電動機無功補償容量的配置。結合應用實例說明采用無功補償技術,提高低壓電網和用電設備的功率因數,已成為節電工作的一項重要措施。
關鍵詞: 節電技術 功率因數 無功補償
Abstract: The power factor of equipment can be used to measure the loss of energy in transmission lines. By refining the technique, we can let the power factor which is below the standard get standardized to save electricity. This article analyses the function of reactive compensation and the ways to choose capacity of compensation. It emphasizes in discussing the configuration of low voltage network and asynchronous motor’s capacity in reactive compensation. By combining with actual examples, this article also explains that using the technique of reactive compensation to improve the power factor of low voltage network and equipment has become an important measure to save electricity.
Key words: Technique of electricity saving ,Power factor, Reactive compensation
1、前言
無功補償,就其概念而言早為人所知,它就是借助于無功補償設備提供必要的無功功率,以提高系統的功率因數,降低能耗,改善電網電壓質量。
無功補償的合理配置原則
從電力網無功功率消耗的基本狀況可以看出,各級網絡和輸配電設備都要消耗一定數量的無功功率,尤以低壓配電網所占比重最大。為了最大限度地減少無功功率的傳輸損耗,提高輸配電設備的效率,無功補償設備的配置,應按照“分級補償,就地平衡”的原則,合理布局。
(1)總體平衡與局部平衡相結合,以局部為主。
(2)電力部門補償與用戶補償相結合。
在配電網絡中,用戶消耗的無功功率約占50%~60%,其余的無功功率消耗在配電網中。因此,為了減少無功功率在網絡中的輸送,要盡可能地實現就地補償,就地平衡,所以必須由電力部門和用戶共同進行補償。
(3)分散補償與集中補償相結合,以分散為主。
集中補償,是在變電所集中裝設較大容量的補償電容器。分散補償,指在配電網絡中分散的負荷區,如配電線路,配電變壓器和用戶的用電設備等進行的無功補償。集中補償,主要是補償主變壓器本身的無功損耗,以及減少變電所以上輸電線路的無功電力,從而降低供電網絡的無功損耗。但不能降低配電網絡的無功損耗。因為用戶需要的無功通過變電所以下的配電線路向負荷端輸送。所以為了有效地降低線損,必須做到無功功率在哪里發生,就應在哪里補償。所以,中、低壓配電網應以分散補償為主。
(4)降損與調壓相結合,以降損為主。